SUPPLY The supply and assembly of the components of the house are understood to be for the UNFINISHED BUILDING AT AN ADVANCED STAGE with TRUSSED RAFTER ROOF | TYPE OF HOUSE Wooden House 60m2 |
ENERGY RATING Almost passive house energy rated A+ or above | NOISE RATING Class 1 |
STRUCTURAL RATING Timber building with seismic resistance class 1 | WALLS Framed external bearing wall structure finished with external wood fibre render with thermal performance coefficient equivalent to: U = 0.135 W/m2 |
ROOF WITH EXPOSED BEAMS The roof with exposed beams supplied has a thermal performance coefficient equivalent to: U = 0.18 W/m2 | STRUCTURES IN SOLID AND/OR LAMINATED WOOD The solid and/or laminated wood structures meet the requirements set out in clause A of section 11.1 of NTC 2018 standards (CE marking of structural elements) |
WINDOWS All the windows and patio doors are triple glazed with double cavity and have Class S profiles (as specified in standard EN 12608). They also have a very high radiation resistance value (12 GJ/m2), well above the limit stipulated by the standard | GUARANTEE The structural guarantee is for ten years |
Wooden cladding 21 x 145 UYVk Spruce AB - horizontal
Air circulation chamber
28x45 mm wooden counter-battens
Breathable waterproof membrane 0.5 mm thick Riwega USB WALL 100
Wooden post structure C24 - 200mm, wall height 2500mm
Thermal insulation, total thickness 200 mm
Vapour barrier 0.2 mm
Horizontal laths 45x45mm – not included in the price
OSB Plate 12mm – not included in the price
Plaster Board 13mm – not included in the price
SUPPLY AND ASSEMBLY OF THE INTERNAL WALLS INCLUDES:
Structure of the walls with wooden posts 45 mm thick, of variable widths (95/145/195 mm)
THE ON-SITE SUPPLY AND INSTALLATION OF THE STRUCTURE FOR THE CREATION OF THE ROOF INCLUDES:
Supporting beams with roof trusses in accordance with the structural calculations
Breathable membrane / RIWEGA DO 135
28 X 45 mm battens
From 1 to 6 – included in the price
From 7 to 15 – NOT included in the price
ALL THE SOLID AND/OR LAMINATED TIMBER STRUCTURES MEET THE REQUIREMENTS
SET OUT IN CLAUSE A) OF SECTION 11.1 OF THE NTC 2018 STANDARDS
(CE MARKING OF STRUCTURAL ELEMENTS)
Included in the price are positions A and TU – from windows specification
Positions: VU and LU are not included in the price
Roof windows are not included in the price
THE SUPPLY OF WINDOWS AND PATIO DOORS IS AS FOLLOWS:
PVC, in white or in a colour selected from our catalogue – colour windows costs extra
Triple glazing with double cavity
Class S profiles
Radiation resistance coefficient equivalent to 12 GJ/m2
Thermal performance coefficients
Uw value = up to 0.50 W/(m2K)
Uf value = 0.95 W/(m²K)
WINDOW DOORS HIGHER THAN 210 WILL BE SUBJECT TO A SURCHARGE
sliding doors / sliding windows are not included in the price
Windows assembly:
Fixed only with clips
Not taped, without window mouldings, without window sills